Urine Drug Testing

Amphetamine (AMP) One Step Rapid Drug Test Device (Urine)

One-step rapid urine test device for Amphetamine (AMP) detection.

CE Certified
ISO 13485
Main image of Amphetamine (AMP) One Step Rapid Drug Test Device (Urine)

Why Choose reOpenTest Toxicology & Drug Monitoring Kits?

Our tests are engineered for accuracy, reliability, and ease of use, ensuring confidence in every result.

Fast Results

Get results in just 5-10 minutes.

Easy to Use

Simple procedure, minimal training required.

Reliable

Accurate and consistent results.

Product Overview

The Amphetamine (AMP) One Step Rapid Drug Test Device is a qualitative immunoassay for the detection of amphetamine in human urine. This rapid test provides a convenient and efficient method for screening individuals for the presence of amphetamine. The easy-to-use format allows for rapid on-site testing, making it suitable for various settings. The test utilizes a simple visual interpretation of results, reducing the need for complex laboratory equipment. A positive result should be confirmed.

Technical Specifications

Detection Target Amphetamine (AMP)
Sample Type Urine
Methodology Immunochromatography
Detection Range Positive/Negative
Reaction Time 5-10 minutes
Storage Conditions 2-30u00b0C
Shelf Life 24 months

Procedure & Interpretation

Step-by-Step Procedure

  1. Collect urine sample in a clean container.
  2. Open the sealed pouch and remove the test device.
  3. Add 3 drops of urine into the sample well of the device.
  4. Read the results after 5 minutes.

Result Interpretation

Positive Result
Positive: Only one colored line appears in the control region. This indicates a positive result for amphetamine.
Negative Result
Negative: Two colored lines appear: one in the control region and one in the test region. This indicates a negative result for amphetamine.
Invalid Result
Invalid: No line appears in the control region. The test is invalid and should be repeated with a new device.

Frequently Asked Questions

Amphetamine is typically detectable in urine for 1-3 days after the last use, but this can vary depending on individual factors.

Refer to the product insert for the specific cutoff concentration of amphetamine for this test device.

Certain medications, such as decongestants, may potentially cause a false positive result. It is important to consider this possibility when interpreting the results. Always confirm with laboratory testing.

Technical Documents

Download product inserts and brochures for detailed information.

No technical documents are available at this time. Please check back soon.